260R Gas Regulator
![](http://beta.gasessentials.com/wp-content/uploads/2018/04/260r-768x768.jpg)
Introduction
•The Model 260 Regulator is a lever operated, spring loaded regulator
•Use with confidence on natural and manufactured gases of non-aggressive nature, including nitrogen, carbon dioxide,
propane, butane, etc.
•Versions available for special applications like indoor applications with no requirement for vent-line
•Fixed factor billing model available (PFM) for applications that require accuracy to +/- 1% absolute pressure
•CSA 6.18 Service Regulator and CSA 6.22 Line Pressure Regulator Approved
Unique Feature
•Upon full regulator failure, outlet pressure is limited to under 1 psi (70 mbar) with 60 psi (4 bar) inlet pressure and full
bore relief discharge. Tested and approved to CSA 6.18 specifications
Characteristics
•Wide inlet pressure range 1-125 psi (0.07-8.6 bar) depending on orifice diameter
•Maximum inlet pressure 150 psi (10.3 bar)
•Maximum allowable operating pressure 125 psi (8.6 bar) depending on orifice diameter
•Lever-operated to accommodate changes in inlet pressure, spring-loaded for increased speed of response
•Various interchangeable orifices for ease of maintenance, customizability and increased turndown ratio to accommodate a
wide range of flow and pressure requirements
•Outlet pressure range from 4“ wc – 5.5 psi (10.0-385 mbar) over 6 spring ranges
•3 different inlet/outlet thread types (NPT, BSPT, BSPP) in ½, ¾, 1“ screwed both in-line (180o) or angle (90o) body
casting
•Various internal relief valve assemblies available (full, limited and none)
•1“ threaded vent connection
•Ease of maintenance due to interchangeable diaphragm casing cartridge
•Various integral safety slam-shut (SSV) models available for pressure/flow shut off protection.
•Custom designed and pre-fabricated regulator meter set assemblies available
Available Constructions
•260 R – full internal relief valve
•260 P – no internal relief valve
•260 SD – safety diaphragm version (internal vent-limiting device)
•260LR-OPCO – limited internal relief valve capacity with integral over-pressure slam-shut device
•260P-OPCO – no internal relief valve capacity with integral over-pressure slam-shut device
•260SD-OPCO SD – safety diaphragm version with integral over-pressure slam-shut device and internal vent limiting
devices (indoor installations only)
•260LR-309 UPCO/OPCO – limited internal relief valve capacity with integral under and over-pressure slam-shut device
•260P-309 UPCO/OPCO – no internal relief valve capacity with integral under and over-pressure slam-shut device
•260SD-309 UPCO/OPCO – safety diaphragm version with integral over and under-pressure slam-shut device and internal
vent limiting devices (indoor installations only)
•PFM Version – fixed factor billing or pressure factor metering version for outlet pressure accuracy of +/- 1% absolute
pressure
•260 F – complete with inlet mess filter
•260 EFV – complete with an excess flow valve
•260SD-309 t OPCO – safety diaphragm version with integral over-pressure slam-shut device and integral vent limiting
device plus thermal trip protection for shut-off at high-temperature limit (indoor installations only)
Materials Of Construction | |
---|---|
Inline Body Casting | Cast Iron or Ductile Iron |
Angle Body Casting | Cast Iron or Ductile Iron |
Diaphragm Casings | Die Cast Aluminum |
Diaphragm | Molded Nitrile Rubber with Nylon Reinforcing |
Valve Head (Seat) | Buna-N Rubber |
Diaphragm Plates | Steel |
Orifice (regulator without SSV) | Aluminum |
Orifice (regulator with SSV) | Brass or Stainless Steel (t-type) |
Vent Screen | Stainless Steel |
Fasteners | Steel |
Top Cap | Molded Plastic or Aluminum |
Springs | Steel |
Lever | Steel |
Relief Valve Assembly | Molded Plastic |
Valve Extension | Aluminum |
O-Rings | Nitrile Rubber |